当前位置:Gxlcms > mysql > 用NET-SNMP软件包开发简单客户端代理(6)

用NET-SNMP软件包开发简单客户端代理(6)

时间:2021-07-01 10:21:17 帮助过:33人阅读

6.3.4 ExampleTable_access.h /*ExampleTable_access.h*/ /* * Note: this file originally auto-generated by mib2c using * :mib2c.access_functions.conf,v 1.9 2004/10/14 12:57:33 dts12 Exp $ */ #ifndef EXAMPLETABLE_ACCESS_H #define EXAMPLETABLE_

6.3.4 ExampleTable_access.h

/*ExampleTable_access.h*/

/*

* Note: this file originally auto-generated by mib2c using

* : mib2c.access_functions.conf,v 1.9 2004/10/14 12:57:33 dts12 Exp $

*/

#ifndef EXAMPLETABLE_ACCESS_H

#define EXAMPLETABLE_ACCESS_H

/** User-defined data access functions for data in table ExampleTable */

/** row level accessors */

Netsnmp_First_Data_Point ExampleTable_get_first_data_point;

Netsnmp_Next_Data_Point ExampleTable_get_next_data_point;

int ExampleTable_commit_row(void **my_data_context, int new_or_del);

void * ExampleTable_create_data_context(netsnmp_variable_list *index_data, int column);

/** column accessors */

long *get_MachineNumber(void *data_context, size_t *ret_len);

char *get_MachineStatus(void *data_context, size_t *ret_len);

u_long *get_CheckTime(void *data_context, size_t *ret_len);

long *get_MonSet(void *data_context, size_t *ret_len);

int set_MonSet(void *data_context, long *val, size_t val_len);

#endif /* EXAMPLETABLE_ACCESS_H */

6.3.5 ExampleTable_checkfns.c

/*ExampleTable_checkfns.c*/

/*

* Note: this file originally auto-generated by mib2c using

* : mib2c.check_values.conf,v 1.8 2004/01/12 00:43:45 rstory Exp $

*/

/********************************************************************

* NOTE NOTE NOTE

* This file is auto-generated and SHOULD NOT BE EDITED by hand.

* Modify the ExampleTable_checkfns_local.[ch] files insead so that you

* can regenerate this one as mib2c improvements are made.

********************************************************************/

/* standard headers */

#include

#include

#include "ExampleTable_checkfns.h"

#include "ExampleTable_checkfns_local.h"

#include "ExampleTable_enums.h"

/** Decides if an incoming value for the MonSet mib node is legal.

* @param type The incoming data type.

* @param val The value to be checked.

* @param val_len The length of data stored in val (in bytes).

* @return 0 if the incoming value is legal, an SNMP error code otherwise.

*/

int

check_MonSet(int type, long *val, size_t val_len,

long *old_val, size_t old_val_len) {

int ret;

/** Check to see that we were called legally */

if (!val)

return SNMP_ERR_GENERR;

/** Check the incoming type for correctness */

if (type != ASN_INTEGER)

return SNMP_ERR_WRONGTYPE;

ret = SNMP_ERR_NOERROR;

/** looks ok, call the local version of the same function. */

return check_MonSet_local(type, val, val_len, old_val, old_val_len);

}

6.3.6 ExampleTable_checkfns.h

/*ExampleTable_checkfns.h*/

/*

* Note: this file originally auto-generated by mib2c using

* : mib2c.iterate.conf,v 5.6 2003/02/20 00:52:07 hardaker Exp $

*/

/***********************************************************************

* This file is auto-generated and SHOULD NOT BE EDITED by hand.

* Modify the ExampleTable_checkfns_local.[ch] files insead.

* (so that you can regenerate this one as mib2c improvements are made)

***********************************************************************/

#ifndef EXAMPLETABLE_CHECKFNS_H

#define EXAMPLETABLE_CHECKFNS_H

/** make sure we load the functions that you can modify */

config_require(ExampleTable_checkfns_local)

/* these functions are designed to check incoming values for

columns in the ExampleTable table for legality with respect to

datatype and value.

*/

int check_MonSet(int type, long *val, size_t val_len, long *old_val, size_t old_val_len);

#endif /* EXAMPLETABLE_CHECKFNS_H */

6.3.7 ExampleTable_checkfns_local.c

/*ExampleTable_checkfns_local.c*/

/*

* Note: this file originally auto-generated by mib2c using

* : mib2c.check_values_local.conf,v 5.2 2004/05/04 23:34:56 hardaker Exp $

*/

/* standard headers */

#include

#include

#include "ExampleTable_checkfns.h"

#include "ExampleTable_enums.h"

/** Decides if an incoming value for the MonSet mib node is legal, from a local implementation specific viewpoint.

* @param type The incoming data type.

* @param val The value to be checked.

* @param val_len The length of data stored in val (in bytes).

* @return 0 if the incoming value is legal, an SNMP error code otherwise.

*/

int

check_MonSet_local(int type, long *val, size_t val_len, long *old_val, size_t old_val_len) {

/** XXX: you may want to check aspects of the new value that

were not covered by the automatic checks by the parent function. */

/** XXX: you make want to check that the requested change from

the old value to the new value is legal (ie, the transistion

from one value to another is legal */

/** if everything looks ok, return SNMP_ERR_NOERROR */

return SNMP_ERR_NOERROR;

}

6.3.8 ExampleTable_checkfns_local.h

/*ExampleTable_checkfns_local.h*/

/*

* Note: this file originally auto-generated by mib2c using

* : : mib2c.check_values_local.conf,v 5.2 2004/05/04 23:34:56 hardaker Exp $

*

*/

#ifndef EXAMPLETABLE_CHECKFNS_H

#define EXAMPLETABLE_CHECKFNS_H

/* these functions are designed to check incoming values for

columns in the ExampleTable table for legality with respect to

datatype and value according to local conventions. You should modify

them as appropriate. They will be called from parent check_value

functions that are auto-generated using mib2c and the parent functions

should NOT be modified.

*/

int check_MonSet_local(int type, long *val, size_t val_len, long *old_val, size_t old_val_len);

#endif /* EXAMPLETABLE_CHECKFNS_H */

6.3.9 ExampleTable_columns.h

/* ExampleTable_columns.h*/

/*

* Note: this file originally auto-generated by mib2c using

* : mib2c.column_defines.conf,v 5.1 2002/05/08 05:42:47 hardaker Exp $

*/

#ifndef EXAMPLETABLE_COLUMNS_H

#define EXAMPLETABLE_COLUMNS_H

/* column number definitions for table ExampleTable */

#define COLUMN_MACHINENUMBER 1

#define COLUMN_MACHINESTATUS 2

#define COLUMN_CHECKTIME 3

#define COLUMN_MONSET 4

#endif /* EXAMPLETABLE_COLUMNS_H */

6.3.10 ExampleTable_enums.h

/* ExampleTable_enums.h*/

/*

* Note: this file originally auto-generated by mib2c using

* : mib2c.column_enums.conf,v 5.2 2003/02/22 04:09:25 hardaker Exp $

*/

#ifndef EXAMPLETABLE_ENUMS_H

#define EXAMPLETABLE_ENUMS_H

#endif /* EXAMPLETABLE_ENUMS_H */

6.4 自定义mib文件MyMib.txt

MyMIB DEFINITIONS::=BEGIN

IMPORTS

enterprises,OBJECT-TYPE,Integer32,TimeTicks

FROM SNMPv2-SMI

TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC;

foxmail OBJECT IDENTIFIER::={enterprises 310}

SecondCounter OBJECT-TYPE

SYNTAX Integer32

ACCESS read-write

STATUS mandatory

DESCRIPTION "This is a one minute counter from year 1970.1.1.0:0 to now"

::={foxmail 1}

WeekTime OBJECT-TYPE

SYNTAX TimeTicks

ACCESS read-only

STATUS mandatory

DESCRIPTION "Recording taday's time and the day sorts in the week"

::={foxmail 2}

ExampleTable OBJECT-TYPE

SYNTAX SEQUENCE OF ExampleEntry

MAX-ACCESS not-accessible

STATUS current

DESCRIPTION

"A list of interface entries. The number of entries is

given by the value of ExampleNumber."

::= { foxmail 3 }

ExampleEntry OBJECT-TYPE

SYNTAX ExampleEntry

MAX-ACCESS not-accessible

STATUS current

DESCRIPTION

"An entry containing management information applicable to a

particular interface."

INDEX { UserIndex }

::= { ExampleTable 1 }

ExampleEntry ::=

SEQUENCE {

UserIndex InterfaceIndex,

UserStatus DisplayString,

CheckTime TimeTicks,

MonSet Integer32

}

InterfaceIndex ::= TEXTUAL-CONVENTION

DISPLAY-HINT "d"

STATUS current

DESCRIPTION

"A unique value, greater than zero, for each interface or

interface sub-layer in the managed system. It is

recommended that values are assigned contiguously starting

from 1. The value for each interface sub-layer must remain

constant at least from one re-initialization of the entity's

network management system to the next re-initialization."

SYNTAX Integer32 (1..2147483647)

UserIndex OBJECT-TYPE

SYNTAX InterfaceIndex

MAX-ACCESS read-only

STATUS current

DESCRIPTION

"A unique value, greater than zero, for each interface. It

is recommended that values are assigned contiguously

starting from 1. The value for each interface sub-layer

must remain constant at least from one re-initialization of

the entity's network management system to the next re-

initialization."

::= { ExampleEntry 1 }

UserStatus OBJECT-TYPE

SYNTAX DisplayString

MAX-ACCESS read-only

STATUS current

DESCRIPTION

"machine status ."

::= { ExampleEntry 2 }

CheckTime OBJECT-TYPE

SYNTAX TimeTicks

MAX-ACCESS read-only

STATUS current

DESCRIPTION

"machine status checking time."

::= { ExampleEntry 3 }

MonSet OBJECT-TYPE

SYNTAX Integer32

MAX-ACCESS read-write

STATUS current

DESCRIPTION

"An example to use set function."

::={ ExampleEntry 4}

END